validate_against_xsd checks a loaded model, a file path or XML bytes against the DesignBuilder.xsd bundled with the package and returns the error messages; an empty list means the XML is valid. For a loaded model this tells you whether saving it would produce a file the schema accepts.

from dsbxml.utils import validate_against_xsd

errors = validate_against_xsd(model)
for message in errors:
    print(message)

Loading is more lenient than the schema: some files that do not validate still load, so validate explicitly when that matters.

Known issue: a building without detailed HVAC has an empty <HVACNetwork></HVACNetwork>, which the model writes back with an <ObjectIDs> child. The schema does not allow that, so such models report an ObjectIDs error after loading even though the source file was valid.